RENOVENT EXCELLENT P300 • HRU system D ≤ 300 m³/h

Heat recovery units with counter-flow heat exchanger for projects with an air flow up to 300 m³/h

Brand

  • Brink

Application

  • Ventilation with heat recovery for residential and non-residential applications

  • Indoor mounting in a frost-free area

Specifications

  • Tension: 230V
  • Protection class: IP30
  • Available in 2 versions: left (L4/0) or right (R4/0) with 4 connections on top

Composition

  • Casing in prelacquered steel plate
  • Round connections with diameter 160 mm
  • Automatic 100% bypass with actuator
  • Condensation tray and drain with connexion dia 32 mm
  • Inner casing in EPS foam for thermal and acoustic insulation

Fan

  • Single inlet centrifugal fan EBM Papst from the latest generation
  • Direct driven EC-motor

Exchanger

  • Static counter-flow heat exchanger made of plastic
  • Complete and automatic bypass

Filter

  • Renovent Excellent P300 has two G3 filters

Accessories

  • 4-positions switch with filter indication, type CVREN 4
  • F7 filter for fresh air, type FSREN EX F7
  • Enthalpy changer, type WTW-H
  • RF remote control (4 positions) with receiver, type RFREN
  • Stench trap, type SIP 32
  • Electric pre-heater, type CVR-VE
  • Humidity sensor, type HRT REN
  • Cable for Renovent, type RJ12
  • Mounting chairs, type MC

Order example

RENOVENT EXCELLENT P300, L4/0

Explanation

  • RENOVENT EXCELLENT P = type of heat recovery unit
  • 300= max airflow m³/h
  • L = left configuration
  • 4/0 = 4 connections on top

Prices

Prices available on request (minimum 8 pieces)

Selection curves

  • Resistance of duct system in Pa
  • Air flow in m³/h

Technical data

  Qv [m³/h]P [W]Lwa [dB(A)]
  Lwa2
Lwa5
Lwa6
Excellent 180Vmin50 @ 7-16Pa16 - 18   
V175 @ 18-40Pa24 - 263231
49
V2100 @ 30-68Pa30 - 423937
56
V3150 @ 60-150Pa62-864845,50
66
Vmax180 @ 150Pa116   
Excellent 300Vmin50 @ 3-7Pa9 - 9,2   
V1100 @ 11-28Pa13,7 - 15,230
3344
V2150 @ 26-66Pa22 - 29,238
3951
V3225 @ 56-142Pa46,8 - 66,244
4560
Vmax300 @ 150Pa10450
5467
Excellent 400Vmin50 @ 3-6Pa8,60   
V1100 @ 6-20Pa9,5 - 1528,5030,5041,50
V2200 @ 25-49Pa29 - 4039,5045,5056
V3300 @ 56-178Pa72 - 985255,5065
Vmax400 @ 150Pa16653,505869,50
Excellent 450Vmin50 @ 2-5Pa9,5   
V1100 @ 5-15Pa11 - 1829,531,542,5
V2200 @ 20-60Pa32 - 4540,546,557
V3300 @ 40-130Pa80 - 1055156,566
V400 @ 150Pa17054,55970,5
Vmax450 @ 100Pa222---

Technical data

  Q [m³/h]P [W]Lwa [dB(A)]
  

Lwa2

Lwa5

Lwa6
Renovent Excellent P300Vmin50 @ 3-7Pa9 - 9,2   
V1100 @ 11-28Pa13,7 - 15,2

30

3344
V2150 @ 26-66Pa22 - 29,2

38

3951
V3225 @ 56-142Pa46,8 - 66,2

44

4560
Vmax300 @ 150Pa104

50

5467

Lwa2 = Sound power level enviromment

Lwa 5 = Sound power level @inlet

Lwa 6 = Sound power level @outlet

Energy efficiency class

 ManualSensorsClock / sensor
Renovent Excellent P300AA+A

1: to the house 2: to outside 3: from the house

4: from outside 5: electrical connection 6: condensate drain

HELPCopyrightSales conditions