PRODUCTS
EShop-number
Password
Welcome to SIG Air Handling
Belgium » English
Group Head Quarters
Group Head Quarters
Belgium
Belgium
Bulgaria
Bulgaria
France
France
Germany
Germany
Hungary
Hungary
Netherlands
Netherlands
Poland
Poland
Romania
Romania

VAV-RSB • Rectangular VAV dampers

  • Rectangular
  • Belimo MP controller

VAV-RSB air flow regulator can be used both for variable and constant flow and, if appropriate, for forced shut-off for both air supply and air exhaust.

Application

  • Regulating of air volumes to change the temperature or air quality in a room
  • Control and regulate the supply air flow and exhaust air flow
  • Airflow range can be set between two set values or as constant airflow

Material

  • Galvanized steel

Composition

  • Operating range is between 2 to 12 m/s
  • Integrated flow measurement with seperate measurement nipples for control and manual measurement
  • The damper has stable synthetic bearings and its shaft is mounted in maintenance free synthetic headings
  • Blade air tightness class 2 in accordance with EN1751 in closed position

Controls

  • Controller type Belimo LMV-D3-MP (5Nm) and Belimo NMV-D3-MP (10Nm) are pressure regulated actuators for pressure independent controls. Settings can be done by using the Assistant App* (smartphone) with NFC connection (Near Field Communication) or by using the service tool ZTH (PC-tool).
  • Operating range 0-10V or 2-10V (Standard set on 0-10V)
  • Units of airflow: l/s or m3/h
  • Minimum adjustable air volume set at air velocity at +/- 2 m/s and maximum adjustable airvolume set at air velocity of 12 m/s
  • Differential pressure range Δp @ Vnom 38 - 500 Pa
  • Running time over the full actuator range : 100s
  • Power consumption 5 Nm: 2W, 3.5VA / 10 Nm: 3W , 5VA
  • Supply voltage 24V AC/DC
  • * Assistant App available in App Store & Google Play Store

Options

  • Insulated version VAV-RSB-I, satndard insulation thickness 30mm
  • Other versions and brands of actuators available upon request

Accessories

  • Sound attenuator, type BTH-B

Order example

  • VAV-RSB 400 X 100 LXH

Explanation:

VAV-RSB = Airflow regulator type

400 X 100 LXH = Dimension of the damper

Sound data

VAV-RSBL600
 H100200300400500
 Vk [m/s]3691236912369123691236912
pS = 125 PaLw [dB/Okt]f [Hz]634555636851606873536371765665737859687681
1254656636849586671516068735261697453637175
2504249545746535861485560635056626452596467
5004447505245485153454951534649525346505254
10004649515348505354485153554952545550525556
20004649515349525456515456585255575954575960
40003943474941465052434751534449525545505456
80003237414336414547384347504045495142475154
pS = 250 PaLw [dB/Okt]f [Hz]635261687256647175586673775968757961707781
1254958657053616973556471755665727758677479
2504653586249566266515864685360666955626872
5004852565850545860515559615156596252576163
10005154575952565961535760615457606255586163
20005356585956586162576062645861636560636566
40004952555751545759525659605356596154586163
80004549525447515456495356585064575951555860
pS = 500 PaLw [dB/Okt]f [Hz]635765727660697680637178826473808467758286
1255363717756667480586876815969778361717984
2504958667055647276596875806170788254748186
5005359636656626669586368715965697261667173
10005962646661646667626467686265686963666970
20006465666666676869686970706970717170717273
40006364656665666768666768696768696968697070
80005961636461636566626566686365676964676970
 L6001000
 H6007008009001000
 Vk [m/s]3691236912369123691236912
pS = 125 PaLw [dB/Okt]f [Hz]635968768162717984647482876575838866768388
1255363717555657377576674795767758057677580
2505259646754616669566368715764697258646973
5004650525447515355475153554851545548515455
10005052555651535657515456575154565851545658
20005457596056596162576062645861636558616365
40004550545647525658495357594954586049545860
80004247515445505456475256584853575948535759
pS = 250 PaLw [dB/Okt]f [Hz]636170778163727983657480856675818666758286
1255867747960697781627179836372808464728084
2505562687257657074596772766068737761687377
5005257616354586264555963655560636655606366
10005558616356596264576063655761646557616465
20006063656662656768636668696467697064676970
40005458616356596264576063655761646657616466
80005155586053576062545861635559626455596264
pS = 500 PaLw [dB/Okt]f [Hz]636775828669788589718087917281889272818892
1256171798463738186647483886575848965758489
2506574818669788590728188937382899474839095
5006166717363687375647074776571757865717578
10006366697064677071656870726669717266697172
20007071727372737475737575767475767774757677
40006869707069707172707172737072737370727373
80006467697066687071676971726870727368707273

Correction factor for other widths

 L [mm]Δps = 125 PaΔps = 250 PaΔps = 500 Pa
 631252505001000200040008000631252505001000200040008000631252505001000200040008000
L = 600 mm200-8-4-6-2-2-5-4-6-5-6-6-3-3-4-3-4-6-5-10-5-3-4-3-3
300-5-3-4-1-1-3-3-4-3-4-4-2-2-3-2-3-4-3-6-3-2-3-2-2
400-3-2-2-1-1-2-2-2-2-2-2-1-1-2-1-1-2-2-4-2-1-2-1-1
500-1-1-100-1-1-1-1-1-100-1-1-1-1-1-2-10-10-1
600000000000000000000000000
700111001111110010111111100
800212011121121111121311111
900322112222221121122421211
1000423112233311222324212122
L = 1000 mm800-2-10-1-1-1-10-1-1-1-1-1-1-1-1-1-1-1-2-1-1-1-1
900-1-10-100-1-1-1-1-100000-1-10-10000
1000000000000000000000000000

  • VAV-RSB = Variable or constant volume damper
  • Q = In-Duct air volume in m³/h
  • Qmin - Qmax = minimum and maximum set point in m³/h
  • Vk = Average velocity in the damper in m/s
  • Ps = Pressure drop over the damper according to the position of the blade
  • Lw [dB/Okt] = Sound power given at a specific pressure drop Ps for the frequencies f[Hz] from 63 up to 8000 Hz in dB
  • Correction factor for other widths in relation to the sizes L=600mm and L=1000mm in dB

Dimensions

VAV-RSBL [mm]H [mm]Vnom [m³/h]kg
200 x 1002001007202.8
200 x 20020020014403.7
300 x 10030010010803.3
300 x 20030020021604.5
300 x 30030030032405.8
400 x 10040010014403.7
400 x 20040020028805.4
400 x 30040030043207.1
400 x 40040040057608.8
500 x 20050020036006.2
500 x 30050030054008.3
500 x 400500400720010.4
500 x 500500500900012.6
600 x 20060020043207.1
600 x 30060030064809.6
600 x 400600400864012.1
600 x 5006005001080014.7
600 x 6006006001296017.2
700 x 300700300756010.9
700 x 4007004001008013.8
700 x 5007005001260016.8
700 x 6007006001512019.7
700 x 7007007001764022.7
800 x 300800300864012.1
800 x 4008004001152015.5
800 x 5008005001440018.9
800 x 6008006001728022.3
800 x 7008007002016025.7
900 x 300900300972013.4
900 x 4009004001296017.2
900 x 5009005001620021
900 x 6009006001944024.8
900 x 7009007002268028.6
1000 x 30010003001080014.7
1000 x 40010004001440018.9
1000 x 50010005001800023.1
1000 x 60010006002160027.3
1000 x 70010007002520031.6

Mounting

HELPCopyrightSales conditions

Requesting information. Please wait a moment...